NeuroGuide
EEG and QEEG Analysis System
NeuroGuide the most informative and
comprehensive Conventional EEG and QEEG analysis system available. Modern and
simple to use Windows Functions provide for Automatic Artifact Rejection,
Dynamic FFTs with Comparisons to FFT Lifespan
Eyes Open and Eyes Closed Norms covering the age from Birth to 82 years
of age. NeuroGuide includes re-Montaging to Average Reference or reference free Current
Source Density (CSD) or Bipolar Montages, JTFA Instantaneous Power, Coherence,
Phase Differences, Burst Metrics and Phase Reset and Bi-Spectral Analyses. NeuroGuide is also
designed for use with the LORETA Key Institute Source Localization
software for registration with the Talarich
NeuroGuide Dynamic Editing Window. Split-Half
Reliability and FFT Normative Comparisons of Selected Segments Reduces Artifact Easy KEY Inst. LORETA
Integration of Selected EEG Segment or the Artifact Free Record Used for
QEEG Report Writing

· Lifespan Normative Comparisons (N = 625): Rel. Power, Abs.
Power, Power Ratios, Coherence, Phase and Amp. Asymmetry.
· Automatic Artifact Rejection with Manual Editing Capability.
· Multiple EEG File Imports (Lexicor, NeuroScan, EDF, Cadwell, ASCII,
Mindset, Mitsar, XLTEK, DeyMed,
BrainMaster & others)
· Instantaneous Split-Half Reliability and test re-test reliability of
Selected EEG Segments.
· Dynamic and Flexible FFT and Normative Comparisons in the Editing Mode.
· Eyes Open and Eyes Closed Lifespan Norms for Linked ears, average ref.
and Current Source Density (CSD) and any bipolar combination of the 10/20
system
· Re-Montage to any Reference Arrangement, e.g., Average reference or
Current Source Density (CSD)
· Export to the
Key Institute LORETA equations and the
· Time domain Output Files Formatted for Easy Import to LORETA Key Inst.
· NeuroGuide Color Bar Graphs of
the Direction and Magnitude of EEG Change Required to Normalize the EEG using
EEG Biofeedback
· EEG Coherence and EEG Phase Raw Values and Z – Score Normative
Comparisons – Birth to 82 Years
· Tab Delimited Output Files for easy importing into statistical programs
and database management systems.
· NeuroStat package for computing
paired t-tests, ANOVA for pre vs. post treatment analysis as well as group
comparisons (add on to the base price).
· NeuroBatch programs for
automatic processing of large numbers of EEG files (add on to the base price).
· Raw or Edited EEG Printouts of Any Montage for Conventional EEG Analyses
· FFT using a 0.5 Hz resolution and 1 Hz Color Maps from 0 to 50 Hz
· Export edited EEG in Lexicor file format and
ASCII
· FFT Normative Power Ratios, including Z scores for Theta/Hi-Beta,
Alpha/Hi-Beta & lo-Beta/Hi-Beta frequency bands
· Mild Head Injury Discriminant Function and TBI
EEG Severity Index (add on to the base price)
· Learning Disability Discriminant Function (add
on to the base price)
· LORETA normative databases of linked ears, average reference, eyes open
and eyes closed - birth to 82 years of age (add on to the base price).
· LORETA source correlations to evaluate dynamic connectivity
· Brain Performance Index – Prediction of Neuropsychological test scores
with a 95% confidence band and including
Full Scale IQ, Verbal I.Q. and Performance I.Q. (add on to the base price)
· JTFA for Instantaneous power, coherence, phase and amplitude asymmetry.
· JTFA feature detection to detect brain state changes such as drowsiness,
sleep and spike & waves.
· A built in Help manual including tutorials.
· 24 channel Mindset EEG acquisition (add on to the base price).
· EEG Burst Metrics
· Cross-Spectra power, co-spectrum and quad-spectrum for in-phase and
out-of-phase EEG analyses
· Complete 171 channel combination topographic maps
· Phase Reset and Phase and Frequency Locking measures
· Time Domain 3-Dimensional Source Localization for spike and wave and
other conventional EEG analyses
· Bi-Spectral Analyses including Log-Log plots of the spectrum and 1/f
distributions
· Up to 128 channel import capacity (128 channels are customized depending
on labeling and channel order – email us at
Real-Time Feedback Between Reliable Artifact Free EEG and the QEEG

Re-Montage NeuroGuide
Window – 85 channels is standard with custom 128 channel imports. You can Select or Create any Montage
With Nearly Instant Screen Update Displays and
Real-Time Comparisons to Norms

Eyes Open & Eyes Closed LifeSpan Norms, Birth to 82 yrs. For Linked Ears, Ave. Reference and
Current Source Density (CSD)
Standard Features of NeuroGuide Deluxe (Basic) Including LifeSpan
Norms
Price: $2,995
EEG Coherence, Phase, Amp. Asym., Rel. Power, Power Ratios Eyes Closed LifeSpan Norms, Dynamic Split-Half Reliability, Dynamic FFT Editing, Automatic Artifact Rejection, Outputs to be used for LORETA 3D Localization, Launch the Key Institute LORETA Viewer, LORETA normative database (birth to 82 years), Tab Delimited Output, Conventional EEG Print Outs, Color Bar Graphs for Minimization of Z Scores, Eyes Open and Eyes Closed Linked Ears, Average Reference and Current Source Density Norms (i.e., Laplacian Norms), Lexicor Export, ASCII Export and multiple EEG file import, EEG burst metrics, time domain LORETA
· Z-Score tables and connection maps for Coherence, Phase, Asymmetry,
Relative Power.
· Tab Delimited Raw-Score and Z-Scores Exportable to Excel, Systat, SPSS and all Database Management programs.
· Topographic maps for Raw-Score and Z-Score Relative Power in 4 frequency
bands
· Topographic maps for Absolute and Relative Power Band Ratios, including
Gamma frequencies (d/q, d/a, d/b; d/γ, q/a, q/b, θ/γ, α/ β, α/γ, β/γ).
· FFT Absolute and Relative Power in Tab Delimited Format
· Split-Half Reliability Values for Each Channel and an Average
Reliability Score all in Tab Delimited Format
· FFT Absolute and Relative Power in 0.5 Hz resolution from 0 to 50 Hz
· Color Bar Graphs of Raw Scores and Z scores Showing how much the EEG
must change so that the Z Score = 0
· 1 Hz Topographic Color Maps, from Delta to the Gamma Frequency Band
including and Absolute Power and Relative Power Z scores
· ASCII EEG Export and ASCII Digital EEG Printout as well as Export in Lexicor file format
· Multiple EEG file import capabilities, e.g., ASCII, Lexicor,
NeuroData, NeuroScan,
Mindset, NeuroGuide, Mitsar,
EDF, BrainMaster, Capscan, Cadwell
· JTFA instantaneous power, coherence, phase and amplitude asymmetry
· Import up to 128 channels (128 channel import customized to the users
labeling and channel order)
· JTFA feature detection to identify deviant EEG events and brain state
changes such as drowsiness and sleep
· LORETA current source analyses using the Key Inst. LORETA program
· LORETA source correlation analyses to evaluate ROI coupling
· Flexible report generator with adjustable color schemes and Z score
ranges
· First and second derivatives of the EEG time series
· Export of JTFA values and derivates
· Flexible export and print capabilities of the EEG traces
· EEG Burst Metrics
· Time Domain Source Localization for conventional EEG analysis
· Event markers with flexible sorting routines
NeuroGuide Seamlessly Integrates to TBI and
Learning Disability (LD) Discriminant Functions
and Correlations with
Neuropsychological Tests (purchased as an add on to the basic system)

NeuroGuide’s NeuroStat
($600 Add On) Seamlessly Integrates Dedicated Comparative
Statistics EEG Pre vs. Post
Treatment or Beginning Session vs. End of Session EEG
and other comparisons

Scientific Publications That NeuroGuide
is Based On:
EEG and Clinical Neurophysiol., 64: 123 - 143, 1986; Science, 236: 1110-1113,
1987; EEG and Clinical Neurophys., 73:
93-106, 1989; Journal of Neuroimaging, 5, 35-45, 1995; J. Neurotrauma,
14: 1-14, 1997; NeuroImage, 8(4),
307-326, 1998. NeuroImage, 7: 352-367, 1998; Brain
Injury,
|
Package
Type (Introductory Offer) |
Part No. |
Price |
|
|
|
NeuroGuide DELUXE (Basic)
EEG REVIEW |
NG-1 |
$2,995 |
|
|
|
·
LifeSpan Normative database – Eyes Open & Closed FFT
and Eyes Closed Birth to 82 years,
Automatic artifact rejection, Launch LORETA Viewer Amplifier
imports include: Lexicor NRS-24, NeuroNavigator NeuroScan, Misar, NeuroData, Cadwell MindSet, BrainMaster & CapScan,
XLTEK, NeuroPrax, etc. |
|
Included in NeuroGuide (Basic) |
|
|
|
·
A single
Mild Head Injury Discriminant Function and TBI
Severity Index or
LD Discriminant and Severity Index = $1,500. Two Discrimiant
Functions and severity indexes as a package = $2,000. ·
Purchase
one discriminant function for $1,500 and then upgrade to a second for another
$500 |
TBI-1 LD-1 |
$1,500 to $2,000 |
|
|
|
·
LORETA Current Density Normative Database – Birth
to 82 years of Age |
LOR-1 |
$1,000 |
|
|
|
·
LORETA 3D Source Correlation Normative Database –
Birth to 82 years of Age |
SC-1 |
$1,000 |
|
|
|
* NeuroBatch –
Automatic Batch analysis software |
NB-1 |
$300 |
|
|
|
·
NeuroStat – An Integrated QEEG Statistics Package |
NS-1 |
$600 |
|
|
|
Brain
Performance Index – Predict Neuropsychological Test Scores |
BPI-1 |
$1, 500 |
|
|
|
Connectivity
Suite ($600) |
CS-1 |
$600 |
|
|
|
Dynamic
Bi-Spectral Analyses ($600) |
BS-1 |
$600 |
|
|
|
NeuroGuide for
BrainMaster
(1 to 4 channels) = $1,200 |
NGBMr-1 |
$1,200
(not an add on) |
|
|
|
2
channel Z Score Biofeedback – Real-time qEEG Guided
biofeedback = $895 4
channel Z Score Biofeedback – Real-time qEEG Guided
biofeedback = $995 |
DLL-2 DLL-4 |
$895 $995 |
|
|
|
Neuropulse/Mindset
-24 EEG Acquisition |
NP-1 |
$500 |
|
|
|
BrainMaster
Discovery-24 EEG Acquisition Software |
DISC-1 |
$500 |
|
|
|
NeuroImaging
Biofeedback – 19 channel real-time Z scores |
NI-1 |
$2,000 |
|
|
|
* Prices do not include costs for shipping and handling or
sales tax, where applicable |
|
|
|
|
|
Ten month
payment plan at 0% interest is
Possible – Call 727-244-0240 |
|
|
|
|
|
|
|
||
For
further information:
Call:
Write to:
Applied
Neuroscience, Inc.
228 176th Terrace Drive
Or E-Mail: qeeg@appliedneuroscience.com
NeuroGuide’s
operates as a "Library function" for information retrieval and analysis
and as an "Accounting and Communications" function by accessing a
table of age matched means and standard deviations from an approximate Gaussian
Distribution and computing age matched Z
scores. There is no intended use for NeuroGuide to provide a medical diagnosis. A trained and qualified person is required
to edit the NeuroGuide EEG samples and to interpret
the numbers based on their competence and training. NeuroGuide should
serve only as an adjunct or in combination to other information that the
clinician may use to render a clinical judgment. FDA 510k indications for use are by qualified
medical or clinical professionals for the statistical evaluation of the human
electroencephalogram (EEG) and competent students and scientists for research
purposes.